1- Department of Orthopedics, Hormozgan University of Medical Sciences. Hormozgan, IR Iran 2- Department of Epidemiology and Statistics, Hormozgan University of Medical Sciences, Hormozgan, IR Iran
1.
Martinet O, Cordey J, Harder Y, Maier A, Buhler M, Barraud GE. The epidemiology of fractures of the distal femur. Injury. 2000; 31 Suppl 3-3[PubMed]
2.
Fracture and dislocation compendium. Orthopaedic Trauma Association Committee for Coding and Classification. J Orthop Trauma. 1996; 10 Suppl 1[PubMed]
3.
Shahcheraghi GH, Doroodchi HR. Supracondylar fracture of the femur: closed or open reduction? J Trauma. 1993; 34(4): 499-502[PubMed]
4.
Hartin NL, Harris I, Hazratwala K. Retrograde nailing versus fixed-angle blade plating for supracondylar femoral fractures: a randomized controlled trial. ANZ J Surg. 2006; 76(5): 290-4[DOI][PubMed]
5.
Christodoulou A, Terzidis I, Ploumis A, Metsovitis S, Koukoulidis A, Toptsis C. Supracondylar femoral fractures in elderly patients treated with the dynamic condylar screw and the retrograde intramedullary nail: a comparative study of the two methods. Arch Orthop Trauma Surg. 2005; 125(2): 73-9[DOI][PubMed]
6.
Krettek C, Muller M, Miclau T. Evolution of minimally invasive plate osteosynthesis (MIPO) in the femur. Injury. 2001; 32 Suppl 3-23[PubMed]
7.
Krettek C, Schandelmaier P, Miclau T, Tscherne H. Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures. Injury. 1997; 28 Suppl 1-30[PubMed]
8.
Johnson KD, Hicken G. Distal femoral fractures. Orthop Clin North Am. 1987; 18(1): 115-32[PubMed]
9.
Stover M. Distal femoral fractures: current treatment, results and problems. Injury. 2001; 32 Suppl 3-13[PubMed]
10.
Dominguez I, Moro Rodriguez E, De Pedro Moro JA, Cebrian Parra JL, Lopez-Duran Stern L. Antegrade nailing for fractures of the distal femur. Clin Orthop Relat Res. 1998; (350): 74-9[PubMed]
11.
Wu CC, Shih CH. Interlocking nailing of distal femoral fractures. 28 patients followed for 1-2 years. Acta Orthop Scand. 1991; 62(4): 342-5[PubMed]
13.
Zlowodzki M, Williamson S, Cole PA, Zardiackas LD, Kregor PJ. Biomechanical evaluation of the less invasive stabilization system, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures. J Orthop Trauma. 2004; 18(8): 494-502[PubMed]
14.
Sanders R, Regazzoni P, Ruedi TP. Treatment of supracondylar-intracondylar fractures of the femur using the dynamic condylar screw. J Orthop Trauma. 1989; 3(3): 214-22[PubMed]
15.
Ricci AR, Yue JJ, Taffet R, Catalano JB, DeFalco RA, Wilkens KJ. Less Invasive Stabilization System for treatment of distal femur fractures. Am J Orthop (Belle Mead NJ). 2004; 33(5): 250-5[PubMed]
16.
Sanders DW, MacLeod M, Charyk-Stewart T, Lydestad J, Domonkos A, Tieszer C. Functional outcome and persistent disability after isolated fracture of the femur. Can J Surg. 2008; 51(5): 366-70[PubMed]
17.
Kregor PJ, Stannard JA, Zlowodzki M, Cole PA. Treatment of distal femur fractures using the less invasive stabilization system: surgical experience and early clinical results in 103 fractures. J Orthop Trauma. 2004; 18(8): 509-20[PubMed]
18.
Bolhofner BR, Carmen B, Clifford P. The results of open reduction and Internal fixation of distal femur fractures using a biologic (indirect) reduction technique. J Orthop Trauma. 1996; 10(6): 372-7[PubMed]
19.
Marti A, Fankhauser C, Frenk A, Cordey J, Gasser B. Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures. J Orthop Trauma. 2001; 15(7): 482-7[PubMed]
20.
Zlowodzki M, Williamson S, Zardiackas LD, Kregor PJ. Biomechanical evaluation of the less invasive stabilization system and the 95-degree angled blade plate for the internal fixation of distal femur Fractures in human cadaveric bones with high bone mineral density. J Trauma. 2006; 60(4): 836-40[DOI][PubMed]
21.
Mast JJR, Ganz R. Planning and Reduction Technique in Fracture Surgery. 1989;
23.
Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H. Minimally invasive plate osteosynthesis: does percutaneous plating disrupt femoral blood supply less than the traditional technique? J Orthop Trauma. 1999; 13(6): 401-6[PubMed]
24.
Farouk O, Krettek C, Miclau T, Schandelmaier P, Tscherne H. Effects of percutaneous and conventional plating techniques on the blood supply to the femur. Arch Orthop Trauma Surg. 1998; 117(8): 438-41[PubMed]
25.
Zlowodzki M, Bhandari M, Marek DJ, Cole PA, Kregor PJ. Operative treatment of acute distal femur fractures: systematic review of 2 comparative studies and 45 case series (1989 to 2005). J Orthop Trauma. 2006; 20(5): 366-71[PubMed]
26.
Moradi A, Pahlavan B, Sadigi A, Pahlavan Y. Treatment of Comminuted Intra-Articular Distal Femur Fractures With Locking Condylar Buttress Compression Plate. J Ardabil Univ Medic Sci. 2012; 12(1): 77-84
27.
Shahosaini GR, Yegane A, Moghtadie M. Comparison of the Surgical Results of Retrograde Intramedullary Nail (Rin) and Locking Condylar Plate (Lcp) in The Treatment of Distal Femoral Fracture . Med J Islam Repub Iran. 2010; 16(62): 131-9
Subject:
Knee surgery Received: 2019/09/9 | Published: 2014/08/15