Volume 8, Issue 3 (8-2021)                   J. Res. Orthop. Sci. 2021, 8(3): 117-126 | Back to browse issues page


XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Norasteh A A, Zarei H. Methods Used for the Assessment of Knee Joint Arthrokinematics: A Review of Literature. J. Res. Orthop. Sci. 2021; 8 (3) :117-126
URL: http://jros.iums.ac.ir/article-1-2169-en.html
1- Department of Corrective Exercise and Sport Injuries, Faculty of Physical Education and Sports Sciences, University of Guilan, Guilan, Iran.
Full-Text [PDF 838 kb]   (512 Downloads)     |   Abstract (HTML)  (890 Views)
Full-Text:   (1094 Views)
1. Background
he knee is a large synovial joint with three internal capsular joint surfaces (two tibiofemoral medial and lateral joints, which bear the weight and a patellofemoral joint surface); it is protected by various tendons, ligaments, muscles, bones, and cartilages [1]. Being exposed to external forces, these elements are more prone to injury [23]. In athletes, these injuries are caused by either severe and sudden impacts or weak and repetitive ones and lead to acute, gradual, or chronic clinical symptoms; they may bring about abnormal arthrokinematic of the knee joint [4].
Abnormal arthrokinematic of the knee joint changes the force distribution and loading mechanisms of different joint structures; thus, it not only augments the primary injury but also it may be a predisposing factor, which increases vulnerability in ligament and other joint structures [5]. Abnormal motion leading to stress occurs at the first few degrees of movement or at the beginning of an activity. It is believed that the major disturbance occurring at the first degrees of motion is an arthrokinematic movement, not an osteokinematic one [6].
Kinematic knowledge is also essential for proper diagnosis and surgical treatment of joint disease and the design of prosthetic devices to restore function. In general, kinematic analysis of human movement can be categorized into two main areas: 
1. Gross movement of the limb segments interconnected by joints, where the relative three-dimensional joint rotation is described by adopting the Eulerian angle system. With proper selection of axes of rotation between two bone segments, the associated finite rotation becomes sequence-independent. This concept is particularly useful since it matches precisely the clinical definition of joint motion. 
2. Detailed analysis of joint articulating surface motion, where generalized three-dimensional, unconstrained rotation and translation are described utilizing the concept of the screw displacement axis [7]. Osteokinematic is the movement of bones relative to one another and can be done actively or passively [8]. Arthrokinematics deals with the real movement of joint surfaces on each other and focuses particularly on momentary movements, which take place in the joint between the joint surfaces [9]. 
Osteokinematics is the branch of biomechanics concerned with the description of bone movement when a bone swings through a range of motions around the axis in a joint, such as with flexion, extension, abduction, adduction, or rotation [10]. Osteokinematics describes clear movements of bones, which are visible from the outside. They are gross movements that happen between two bones. They arise from rotation around the joint axis. Osteokinematics differs from arthrokinematics. In general, osteokinematics means bone movement and arthrokinematics is joint movement (represents the small movements happening at the joint surface itself) [11]. Arthrokinematics refers to the movement of joint surfaces. 
Three main types of arthrokinematic motion occur between two joint surfaces: rolling (rotary or angular), gliding (sliding), spinning (rotational). The angular movement of bones in the human body occurs as a result of a combination of rolls, spins, and slides. A roll is a rotary movement when one bone rolls on another. A slide is a translatory movement, sliding of one joint surface over another [10]. Most the joint movements are a combination of the three [12]. Normal osteokinematic motion is not possible without arthrokinematic motion [13]. One of the factors that predict the complexity of human joints is their arthrokinematic movements. Even though these movements are not voluntary, they are essential for the movability and the natural functioning of the joint [14]. Studies have identified perturbation in arthrokinematic motion as the cause of movement disorders that result in the degradation of knee joint surfaces [15].
Hence, studying joint arthrokinematic motion parameters can be valuable to health professionals in terms of diagnosis of illnesses and injuries of the joint, assessment of treatment results, and identifying the type and degree of injury. This is the case when there is no exhaustive study to set how kinematic parameters of the knee could be measured and assessed, or whether assigning a numerical value to arthrokinematic movements is feasible or not. As a result, the present study was a review of arthrokinematic movements of the knee joints in order to provide exhaustive data about the assessment of accessory (arthrokinematic) movements of the knee and the required tools.
Objectives
An exhaustive review of the methods for the assessment of knee joint arthrokinematics is provided. 
2. Methods
This is a systematic review based on guidelines of preferred reporting items for systematic reviews and meta-analyses (PRISMA). 
Search strategy
Primary sources were obtained from nine databases, including ScienceDirect, MEDLINE/PubMed, LILACS, SCOPUS, CENTRAL (Cochrane Central Register of Controlled Trials), CINAHL, PEDro, Web of Science, and Google Scholar. The search period covered years from inception to February 2020. These electronic databases were searched using a combination of the following keyword groups: knee* and arthrokinematics* or knee arthrokinematics or accessory movement* and motion quality of the knee* or in vivo knee kinematics or three-dimensional movement* and range of motion. 
Eligibility criteria
Search for articles was narrowed down by title and articles in the English and Persian languages, human studies, original articles, and review articles were included. Once the search results were gathered, the title and then the summary of the articles were studied. If the articles matched the inclusion criteria, they were used in the review; otherwise, they were discarded.
Study selection
At the first step, titles and abstracts of descriptive articles were examined with a focus on assessment methods of knee joint arthrokinematics published in English and Persian. A research assistant independently studied the abstracts of articles. In the second phase, the whole text was studied according to the following factors: indicator release (methods for knee joint arthrokinematic assessment) and definition of the target group. The whole text was checked by a single researcher. Also, a senior researcher checked the final list of the articles in order to make sure they all matched the purpose of the research. Target group definition implies whether it is specified which joint (e.g. knee, ankle, waist, etc.) the arthrokinematic assessment was done onto. In cases where the tool was used other than knee joint, the article was discarded. A summary of descriptive information was gathered by the research assistant and checked by the senior researcher. A sample chart (Figure 1) was used for the extraction of information on the target group, arthrokinematic assessment of knee joint, and their results (Table 1).





Quality evaluation

Physiotherapy Evidence Database “Remote Optics” (PEDro) was used to calculate the scores of quality assessment for the eligible studies. The total PEDro score was 11 and incorporated statistical analysis and evaluation criteria of internal validity. Studies that scored 7-11 were considered methodologically “high”, 5 to 6 were “fair”, and ≤4 were considered “poor” [16].
3. Results
The process of selection of the articles is shown in Figure 1. A total number of 155 articles were found from ScienceDirect, MEDLINE/PubMed, LILACS, SCOPUS, CENTRAL (Cochrane Central Register of Controlled Trials), CINAHL, PEDro, Web of Science, and Google Scholar. By checking the sources of the articles, six more articles were added. After the omission of duplicates, 121 abstracts were chosen for the review. After further study of the titles and abstracts, 86 articles were discarded and the number of the articles to be read fully was cut down to 35. After studying the full texts, 14 articles, which had studied the methods for arthrokinematic assessment of knee joint were chosen, and their results are reported in Table 1. By classifying the instruments, it was found that studies of four different measurement methods, including static, dynamic, functional, and qualitative had examined the arthrokinematic movements of the knee (Table 2).


According to the PEDro Scale, all studies scored above 7; therefore, studies examining the assessment methods of knee joint arthrokinematics were of the high-quality category (Figure 1).
4. Discussion
The present review was done to study the methods for the assessment and measurement of arthrokinematic motion of knee joint. It was observed that different methods were used to study arthrokinematic motion of the knee joint. Here, 14 articles (classified in four different measurement methods, including static, dynamic, functional, and qualitative) were specified and their methods were further examined. 
Tools measuring static knee arthrokinematic movements
Daniel et al. designed the first instrument for measuring the glide of the tibia on the femur (MEDmetnc Arthrometer, model KT1000). This tool was primarily designed to diagnose the degree of tear in anterior and posterior ligaments in the knee. Previously, through functional tests (such as Lachman test, Anterior Drawer Test, Jerk, etc.) tears in knee ligaments were diagnosed, and these tests qualitatively scrutinized the degree of glide of the tibia on femur and spotted tears in anterior and posterior knee ligaments. However, it was designed to measure glide of the tibia on femur numerically and measured the glide with an accuracy of up to 0.5 mm [17]. In keeping with the present study and similar to this tool, Robert et al. designed and built a machine called GNRB laxity measurement. It performs the same task as Arthrometer but its accuracy is reported as 0.1 mm [14]. Fujie et al. introduced an instrument called Robotic Testing System, an earlier version of which was designed years earlier. This instrument, however, had advantages, including enhancing repeatability of the situation from 0.5 to 0.05, as well as controllability of the applied force and, as a result, motion control. The machine was designed for synovial joints and was capable of measuring the degree of motion, or gliding of the joint in arthrokinematic terms. This tool fixed the proximal bone, the force was exerted on the distal bone, and consecutively the movement of the distal bone was measured relevant to the proximal bone. Force and motion were measured by a sensor connected to a computer [18]. Vergis et al. offered Electrogoniometer and Fluoroscopy for knee arthrokinematics measurement, which assessed rotation and linear movement of the tibia on the femur [1920]. Moreover, Amerinatanzi et al. used MRI and an automated Matlab-based measurement to examine tibia slope on the femur [21]. Interestingly, all the existing tools measure static knee arthrokinematic movement, and a few studies have measured dynamic movement.
Tools measuring dynamic knee arthrokinematic movements 
Hollman et al. used two cameras and a software program to analyze weighed and weight-free knee arthrokinematic movement. They reported that rolling movement was more frequent in the weighted state than the weight-free state in the final phase of knee extension [22]. Similarly, Tashman et al. studied static and dynamic knee arthrokinematics movement. They performed biplanar knee stereo radiography and measured tibial rotation on the femur (flexion, extension, abduction, adduction, internal rotation, and external rotation) [23]. Bey et al. also applied stereo radiography but used their own model for the analysis of patellofemoral arthrokinematic motion. They reported highly accurate results but only measured static movement [24]. Wu et al. utilized the VICON 3D motion system to examine tibial angle, velocity, speed, and linear movement on the femur [25]. They measured dynamic arthrokinematic motion in walking mode but failed to report the accuracy of their measurements. There are also studies that measured functional and real-speed knee arthrokinematic movement. 
Tools measuring functional and real-speed knee arthrokinematic movements 
Guan et al. examined fluoroscopy data in functional mode [26], which were studied by Vergis et al. in static mode. Guan et al. measured real and functional performance to help with rehabilitation, diagnosis, and treatment decisions. Yang et al. used computed tomography to study kinematic and arthrokinematics movements, and the path of the center of closest contact in normal people compared to those with an ACL injury during walking and running practices. They showed that anterior-posterior translations were significantly larger in ACL-deficient than unaffected knees, and found that closest contact points on the femur in ACL-deficient knees were consistently more anterior in the lateral compartment [27]. However, there are studies that used easy-to-use, simpleand inexpensive tools for the analysis of knee arthrokinematic movements.
Tools measuring qualitative knee arthrokinematic 
Bączkowicz et al. used vibroarthrography to evaluate the quality of knee arthrokinematic movements in individuals with osteoarthritis. They measured the mean, speed, and fluctuation of knee motion using an accelerator sensor connected to the patella [28]. Motion quality was measured before and after rehabilitation, prediction, and diagnosis. The advantage of this model to other tools is that it is easy-to-use, inexpensive, and needs no advanced high-tech instrument. Jonak et al. used EEMD-RQA algorithms to study arthrokinematic movements and also used vibration signals to measure the quality of motion [29]. In this model, the internal level of joints can be examined without invasive intervention. 
The results of the study of static knee arthrokinematic assessment methods showed that the measurement accuracy of these tools at 0.5 mm [17] reaches 0.05 mm and the error rate decreases by one percent [18]. This indicates that, over time, the accuracy of the tools used to measure knee arthrokinetic movements increases statically. In addition to tibial transitional motions relative to the femur, arthrokinematic rotational movements were also measured [1920], but the disadvantages of these methods are that they evaluate arthrokinematics in a static state, while all arthrokinematic movements are performed in a functional and dynamic state. Over time, VICON 3D motion system and fluoroscopy instruments were developed to measure knee arthrokinematics, which is an advantage over the static method [20, 25]. These tools are evaluated by a dynamic and functional arthrokinematic method, and the data obtained from these tools are more reliable. 
Fluoroscopy measurement accuracy has been reported to be 0.4 mm, which is lower than static methods; however, the accuracy of the VICON 3D motion system tool has not been reported, and future studies need to focus more on the measurement accuracy of these tools. Arthrokinematics were also studied using accelerator sensors [28, 29]. The advantage of these methods over previous studies is that they are simple and exploit inexpensive tools and evaluate the speed, acceleration, and quality of arthrokinematic movements. However, the accuracy of these tools has not been reported, which requires further studies to check for validity and accuracy. Summarizing the studies, it can be concluded that the instruments used to evaluate static arthrokinematics of the knee have a higher measurement accuracy than other instruments, but evaluate limited factors, while dynamic assessment methods and accelerator sensors evaluate several factors of knee arthrokinematics. Nevertheless, the accuracy of these tools needs to be further evaluated. The present study was systematic but offered no qualitative assessment of the literature. Though all the articles reviewed in this attempt were obtained from authentic journals, the results should be generalized with caution. Moreover, only articles in Persian and English were selected for analysis and there may be similar studies in other languages that were not included in our assessments. Considering the above limitations, it is suggested that further studies perform more qualitative analyses. It is also suggested that researchers examine arthrokinematic movements in other synovial joints to see what tools are good for this purpose.
5. Conclusion
Results of our analysis showed that the literature is rich with a variety of instruments for measuring knee arthrokinematic movements. Earlier studies had focused on the translational motion to examine the static movement of knee. However, dynamic knee arthrokinematic movement was later given more attention. There were some studies that used inexpensive and easy-to-use instruments for the analysis of the quality of knee arthrokinematic movements in individuals with knee injuries compared to normal knee functions.

Ethical Considerations
Compliance with ethical guidelines

There were no ethical considerations to be considered in this research.

Funding
This research did not receive any grant from funding agencies in the public, commercial, or non-profit sectors.

Authors' contributions
Both authors equally contributed to preparing this article.

Conflict of interest
The authors declared no conflict of interests.

References
  1. Jabalameli M, Rahbar M, Bagherifard A, Hadi H, Moradi A, Radi M, et al. Evaluation of distal femoral rotational alignment according to transepicondylar axis and Whiteside’s line: A study in Iranian population. J Res Orthop Sci. 2014; 1(3):22-8. [DOI:10.5812/soj.24626]
  2. Norouzi S, Esfandiarpour F, Shakourirad A, Salehi R, Akbar M, Farahmand F. Rehabilitation after ACL injury: A fluoroscopic study on the effects of type of exercise on the knee sagittal plane arthrokinematics. Biomed Res Int. 2013; 2013:248525. [DOI:10.1155/2013/248525]
  3. Moghtadaei M, Abedi M, Yeganeh A, Yahyazadeh H, Hossienzadeh N, Moeini J, et al. Graft inclination angle is associated with the outcome of the anterior cruciate ligament reconstruction. J Res Orthop Sci. 2018; 5(4):e83764. [DOI:10.5812/soj.83764]
  4. Schmitz RJ, Shultz SJ. Anterior knee stiffness changes in laxity “responders” versus “nonresponders” across the menstrual cycle. J Athl Train. 2013; 48(1):39-46. [DOI:10.4085/1062-6050-47.6.07]
  5. Joseph MF. Clinical evaluation and rehabilitation prescription for knee motion loss. Phys Ther Sport. 2012; 13(2):57-66. [DOI:10.1016/j.ptsp.2011.10.002]
  6. Adhikari SK, Roy RK, Bhattacharyya S, Datta I. Arthrokinematics revisited at knee. Int J Basic Appl Med Sci. 2012; 2(2):1-14. https://www.cibtech.org/J-MEDICAL-SCIENCES/PUBLICATIONS/2012/JMS-02-02/01...002%20Swapan%20Adhikari....Arthrokinematics...Knee...pdf
  7. An KN, Chao EY. Kinematic analysis of human movement. Ann Biomed Eng. 1984; 12(6):585-97. [DOI:10.1007/BF02371451]
  8. Anderst WJ, Tashman S. Using relative velocity vectors to reveal axial rotation about the medial and lateral compartment of the knee. J Biomech. 2010; 43(5):994-7. [DOI:10.1016/j.jbiomech.2009.11.014]
  9. Rostislav VK. Efficacy of soft tissue application, manually-therapeutical techniques for knee arthrokinematics recovery complex in patients after arthroscopic meniscectomy. Int J Med Res Health Sci. 2015; 4(3):560-5. [DOI:10.5958/2319-5886.2015.00108.3]
  10. Smith MD, Vitharana TN, Wallis GM, Vicenzino B. Response profile of fibular repositioning tape on ankle osteokinematics, arthrokinematics, perceived stability and confidence in chronic ankle instability. Musculoskelet Sci Pract. 2020; 50:102272. [DOI:10.1016/j.msksp.2020.102272]
  11. Kage CC, Akbari-Shandiz M, Foltz MH, Lawrence RL, Brandon TL, Helwig NE, et al. Validation of an automated shape-matching algorithm for biplane radiographic spine osteokinematics and radiostereometric analysis error quantification. Plos One. 2020; 15(2):e0228594. [DOI:10.1371/journal.pone.0228594]
  12. Marsh C. The development and application of an arthrokinematic biomarker for the early detection of osteoarthritis [PhD. Dissertation]. United States: University of Pittsburgh; 2014. https://www.proquest.com/openview/defa8d65b648c95af969651c0a02e8a2/1?pq-origsite=gscholar&cbl=18750
  13. Teyhen DS, Flynn TW, Childs JD, Abraham LD. Arthrokinematics in a subgroup of patients likely to benefit from a lumbar stabilization exercise program. Phys Ther. 2007; 87(3):313-25. [DOI:10.2522/ptj.20060253]
  14. Robert H, Nouveau S, Gageot S, Gagniere B. A new knee arthrometer, the GNRB: Experience in ACL complete and partial tears. Orthop Traumatol Surg Res. 2009; 95(3):171-6. [DOI:10.1016/j.otsr.2009.03.009]
  15. Scarvell JM, Galvin CR, Perriman DM, Lynch JT, van Deursen RW. Kinematics of knees with osteoarthritis show reduced lateral femoral roll-back and maintain an adducted position. A systematic review of research using medical imaging. J Biomech. 2018; 75:108-22. [DOI:10.1016/j.jbiomech.2018.05.007]
  16. Maher CG, Sherrington C, Herbert RD, Moseley AM, Elkins M. Reliability of the PEDro scale for rating quality of randomized controlled trials. Phys Ther. 2003; 83(8):713-21. [DOI:10.1093/ptj/83.8.713]
  17. Daniel DM, Stone ML, Sachs R, Malcom L. Instrumented measurement of anterior knee laxity in patients with acute anterior cruciate ligament disruption. Am J Sports Med. 1985; 13(6):401-7. [DOI:10.1177/036354658501300607]
  18. Fujie H, Mabuchi K, Woo SL-Y, Livesay GA, Arai S, Tsukamoto Y. The use of robotics technology to study human joint kinematics: A new methodology. J Biomech Eng. 1993; 115(3):211-7. [DOI:10.1115/1.2895477]
  19. Vergis A, Gillquist J. Sagittal plane translation of the knee during stair walking. Comparison of healthy and anterior cruciate ligament--deficient subjects. Am J Sports Med. 1998; 26(6):841-6. [DOI:10.1177/03635465980260061801]
  20. Vergis A, Hammarby S, Gillquist J. Fluoroscopic validation of electrogoniometrically measured femorotibial translation in healthy and ACL deficient subjects. Scand J Med Sci Sports. 2002; 12(4):223-9. [DOI:10.1034/j.1600-0838.2002.00263.x]
  21. Amerinatanzi A, Summers RK, Ahmadi K, Goel VK, Hewett TE, Nyman E. Automated measurement of patient-specific tibial slopes from MRI. Bioengineering. 2017; 4(3):69. [DOI:10.3390/bioengineering4030069]
  22. Hollman JH, Deusinger RH, Van Dillen LR, Zou D, Minor SD, Matava MJ, et al. Tibiofemoral joint-surface motions in weight-bearing and non-weight-bearing movement. J Sport Rehabil. 2003; 12(2):143-61. [DOI:10.1123/jsr.12.2.143]
  23. Tashman S, Kolowich P, Collon D, Anderson K, Anderst W. Dynamic function of the ACL-reconstructed knee during running. Clin Orthop Relat Res. 2007; 454:66-73. [DOI:10.1097/BLO.0b013e31802bab3e]
  24. Bey MJ, Kline SK, Tashman S, Zauel R. Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion. J Orthop Surg Res. 2008; 3:38. [DOI:10.1186/1749-799X-3-38]
  25. Wu R-Y, Huang Y-Y, Chiang W-H, Chen W-Y. Measurement of knee arthro-kinematic patterns in young individuals with back knee gait. Physiotherapy. 2015; 101(S 1):E1664-5. [DOI:10.1016/j.physio.2015.03.062]
  26. Guan S, Gray HA, Keynejad F, Pandy MG. Mobile biplane X-ray imaging system for measuring 3D dynamic joint motion during overground gait. IEEE Trans Med Imaging. 2015; 35(1):326-36. [DOI:10.1109/TMI.2015.2473168]
  27. Yang C, Tashiro Y, Lynch A, Fu F, Anderst W. Kinematics and arthrokinematics in the chronic ACL-deficient knee are altered even in the absence of instability symptoms. Knee Surg Sports Traumatol Arthrosc. 2018; 26(5):1406-13. [DOI:10.1007/s00167-017-4780-7]
  28. Bączkowicz D, Skiba G, Szmajda M, Vařeka I, Falkowski K, Laudner K. Effects of viscosupplementation on quality of knee joint arthrokinematic motion analyzed by vibroarthrography. Cartilage. 2021; 12(4):438-47. [DOI:10.1177/1947603519847737]
  29. Jonak J, Karpinski R, Machrowska A, Krakowski P, Maciejewski M. A preliminary study on the use of EEMD-RQA algorithms in the detection of degenerative changes in knee joints. IOP Conf Ser Mater Sci Eng. 2019; 710:012037. [DOI:10.1088/1757-899X/710/1/012037]
Type of Study: Review Paper | Subject: Knee surgery
Received: 2021/06/1 | Accepted: 2021/07/25 | Published: 2021/08/1

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Journal of Research in Orthopedic Science